• Affordable Optical Coherence Tomography Imaging System
• Ideal for Biological Sample Imaging, Sample Characterization, and OCT Education
• Compact Form Factor Tabletop Device
The Lumedica OCT Imaging System is an all-in-one high resolution Optical Coherence Tomography Imaging
System. Designed as an affordable alternative to prohibitively expensive and complex units, the system
provides competitive resolution, frame-rate, and power specifications at an industry-leading price. With a laser
centered at 840nm, this OCT Imaging System is ideal for inspection at depths of up to 2.8mm in air, and to
2mm in tissue. The Lumedica OCT Imaging System features axial resolutions of 5μm and lateral resolutions
of 15μm, matching the performance of much more expensive units. With a compact form factor, integrated
computer, and intuitive graphical user interface for laboratory or field use, the Lumedica OCT Imaging System
is an ideal tool for users of all experience levels. An optional workstation package includes a scanner stand with
vertical stage, large monitor, as well as a wireless mouse/keyboard combination to interface with the device.
Image Size: 512 x 512 pixels
A-Scan Line Rate: 15,000/s
Output Power: 750μW Max
Depth Resolution: 7μm in air, 5μm in tissue
B-Scan Image Rate: 22/s
System Size (W x D x H): 14" x 7.5" x 6"
Transverse Resolution: 15μm
Center Wavelength: 840nm
Moku:Lab Multi-Instrument Device
system?integratable
new?design
military
EO?designed?&?manufactured
new?low?price
call?for?OEM?volume?discounts
made?in?the?USA
CE?marked?and?approved
for?info?on?website
hazardous?material
Scanner Size (W x D x H): 2.7" x 1.7" x 7"
Scan Range: 7 x 7mm
Sensitivity (OSNR): 100 dB
System Weight: 6 lbs.
Shop www.edmundoptics.co.uk – latest pricing – availability – new products – over 34,000 items 449
optical metrology optical production spectroscopy detection laboratory kits
• Two Models with 5 or 12 Selectable Instruments
• 2 Channel Analog (BNC) Inputs and Outputs
• Control and Switch Instruments Remotely via Wifi Connected iPad®
The Moku:Lab Multi-Instrument Device eliminates the need for multiple laboratory testing and measurement devices
by combining them into one unique, compact design. The device is remotely controlled via an intuitive, robust
interface on an ad hoc Wi-Fi connected iPad® that enables hand held real time device switching and measurement
readout. Python, LabVIEW™, and MATLAB® control are also available via Ethernet connection. The Moku:Lab
Multi-Instrument Device couples high-speed analog inputs and outputs to fast reconfigurable digital signal processing
and measures, records, or generates signals from DC to 200 MHz. Settings such as scales, measurements,
cursors, and input impedance are saved automatically when switching between instruments for consistent measurements.
The device also allows for saving and sharing data instantaneously using an 8GB removable memory card
and internet connected iPad® via email, Dropbox®, and iCloud® in MAT and .CSV formats. Note: iPad® not included.
Moku:Lab Multi-Instrument Device
Description Stock No. Price
Moku:Lab Multi-Instrument Device #13-756 £2,975.00
Moku:Lab Multi-Instrument Device - Full-suite Bundle #37-045 £8,499.15
GENERAL AND ENVIRONMENTAL CHARACTERISTICS
Power Consumption: 20 W (typical); 30 W (when charging USB)
Power voltage range 100 to 240 V, 50/60 Hz
Temperature: Operating: 0 to +45°C
Non-operating: -10 to +60°C
Diameter: 220mm
Height: 43mm
Weight: 3.73 lbs
Security: Kensington lock compatible
ANALOG INPUTS
Channels: 2 (BNC)
Bandwidth: (-3 dB) 200 MHz into 50 Ω
Sampling Rate: 500 MS/s per channel
Resolution: 12-bit
Voltage Range: 1 Vpp / 10 Vpp
Input Impedance: 50 Ω / 1 MΩ
Input Coupling: AC / DC
AC Coupling Corner (-3 dB): 100 Hz into 50 Ω
30 Hz into 1 MΩ
SNR: 60 dBFS (per sample)
Input Referred Noise: 30 nV/√Hz above 100 kHz
ANALOG OUTPUTS
Channels: 2 (BNC)
Bandwidth (-3 dB): >300 MHz
Sampling Rate: 1 GS/s per channel
Resolution: 16-bit
Voltage Range: 2 Vpp into 50 Ω
Output Impedance: 50 Ω
Output Coupling: DC
INSTRUMENTS INCLUDED
(BOTH MODELS)
1. Oscilloscope
2. Arbitrary Waveform
Generator
3. Waveform Generator
4. Data Logger
5. Spectrum Analyzer
INSTRUMENTS INCLUDED
(#37-045)
6. Lock-in Amplifier
7. PID Controller
8. Digital Filter Box
9. Frequency Response
Analyzer
10. Laser Lock Box
11. Phasemeter
12. FIR Filter Builder
Spectrum Analysis Power Supply
And Tubes
Spectrum Tubes: 100mm Long Active Area
Description Stock No. Price
Air #37-411 £50.15
Argon (Ar) #60-909 £50.15
Carbon Dioxide (CO2) #60-914 £50.15
Deuterium (2H) #37-413 £72.25
Helium (He) #60-907 £50.15
Hydrogen (H2) #60-906 £58.65
Krypton (Kr) #60-915 £50.15
Mercury Vapor (Hg) #60-908 £67.15
Neon (Ne) #60-910 £50.15
Nitrogen (N2) #60-911 £50.15
Oxygen (O2) #60-912 £50.15
Water Vapor (H2O) #60-913 £58.65
Xenon (Xe) #60-916 £58.65
When observed
through a spectroscope,
the emission
lines corresponding
to the energy transition
levels
of
the gaseous
atoms or molecules
will appear
as distinct
components. The spectral
output
for each tube
type can be found in common
references
such as the
Handbook
of Chemistry
and Physics
(CRC Press).
One spectrum
tube assembly
(as pictured)
consists
of
a power supply
and interchangeable spectrum
tubes,
each sold separately.
Spectrum Analysis Power Supply
5,000V 10mA (max), on/off switch,
6 ft. cord, 3" L x 4.5" W x 14.5" H
230V Power Supply: #71-560 £233.75
caution:?laser
harsh?environment?optics
Lumedica OCT Imaging System
Lumedica OCT Imaging System
Description Stock No. Price
OQ LabScope 2.0 OCT Imaging System #13-639 £8,495.75
Workstation Package (stand, monitor, wireless mouse, and keyboard) #37-140 £420.75
/www.edmundoptics.co.uk
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/